Carbon monoxide detector says 13... is this safe?




laura


I read somewhere that 1-70 you could expieriance fatigue, vomiting, dizzyness, ect. but it's not deadly. is this true? how do you get the carbon monoxide levels to go down? any help on this would be great, thanks!


Answer
http://www.cpsc.gov/cpscpub/pubs/466.html

Standard for Action Levels
The following action levels have been defined as minimums for BPI certified Carbon Monoxide Analysts. Analysts may work for a government agency or business entity that has adopted more stringent standards than the ones defined in this document. As such, CO Analysts may enforce those higher standards. Under no circumstances shall a BPI certified CO Analyst recognize less stringent standards or ignore conditions in excess of the defined action levels. The action levels are considered net indoor ambient readings - i.e. - indoor ambient minus outdoor ambient readings.

0 to 9 parts per million (ppm)
Normal - No Action: Typical from: outdoor sources, fumes from attached garages, heavy smoking, fireplace spillage and operation of unvented combustion appliances. With ambient conditions in this range, analysts may continue testing sequences.

10 to 35 parts per million (ppm)
Marginal: This level could become problematic in some situations. Actions: Occupants should be advised of a potential health hazard to small children, elderly people and persons suffering from respiratory or heart problems. If the home has an attached garage, document CO levels in garage. Accept this level as normal for unvented appliances but not for vented appliances. If unvented appliances are in operation, recommend additional ventilation in the areas of operation. With ambient conditions in this range, analysts may continue testing to locate the CO source.

36 to 99 parts per million (ppm)
Excessive: Medical Alert. Conditions must be mitigated. Actions: Ask occupants to step outside and query about health symptoms. Advise occupants to seek medical attention. If occupants exhibit any symptoms of CO poisoning, have someone drive them to a medical facility. Enter the building, open doors and windows to ventilate the structure. Turn off all combustion appliances until the CO level has been reduced to safe levels. If forced air equipment is available, continuos operation of the air handler is recommended at this time. If the home has an attached garage, document CO levels in garage. Test combustion appliances one at a time to determine the source of CO production. If an appliance is determined to be the source of CO production, it should be shut off and not used until a qualified technician with proper test equipment can service it.

100 - 200 parts per million (ppm)
Dangerous: Medical Alert. Emergency conditions exist. Actions: Evacuate the building immediately and check occupants for health symptoms. Advise all occupants to seek medical attention. Occupants should have someone else drive them to a medical facility. If occupants exhibit symptoms of CO poisoning, emergency service personnel must be called. Evacuation is important, but Analysts must not subject themselves to excessive conditions. Maximum exposure time is 15 minutes. Open all doors and windows that can be done quickly. If the home has an attached garage, document CO levels in garage. Disable combustion appliance operation. Continually monitor indoor ambient levels while moving through the building. Once the atmosphere within the structure has returned to safe levels and the appliances have been turned back on, locate the source of CO production for corrective measures.

Greater than 200 parts per million (ppm)
Dangerous: Medical Alert. Emergency conditions exist. Actions: Evacuate the building immediately and check occupants for health symptoms. Advise all occupants to seek medical attention. Occupants should have someone else drive them to medical facility. If occupants exhibit symptoms of CO poisoning, emergency service personnel must be called. Evacuation is important, but analysts must not subject themselves to these conditions. Do not stay inside or re-enter the building until conditions have dropped below 100 ppm. Open all doors and windows that can be done quickly without entering the structure. Call the local utility to shut off gas supply (if applicable and necessary). If the home has an attached garage, document CO levels in garage if possible to do so without being subjected to high levels of CO. Once the atmosphere within the structure has returned to safe levels, restore fuel supply to appliances. Operate and test the appliances one at a time to determine the source of CO production.

Carbon Monoxide detector went off?




delia


My CO detector went off, but the voice said 0 PPM. It's only a month old. On the ceiling in the finished basement. It's not near any lights. It's in a separate room as the furnace.
Should I be concerned?

Add info: I bought it because a very old one I had in that spot went off. I called 911, the firemen closed the windows (I opened them when it went off) turned up the thermostats; said they couldn't find any readings and told me to buy a new one.

The CO detector is up again and hasn't gone off again. Should I call 911?
Thank you for your responses STEVEN F and adam/penny. I will look for someone to come out and test. It was weird it went off the one time saying go to fresh air 0 PPM, but for no reason. And 0 PPM is nothing, so that's why I came here to ask.
When the firemen came that day they went right up to the running furnace and got nothing. I don't know where else the problem could come from.

Anyway, thank you again. You are both very helpful.



Answer
most of us don't realize it but those detectors come in different co2 detection modes..
i had a similar problem with a new one i bought that went off frequently and after having service people come out to the house they were unable to detect anything wrong. however they said the detector i had purchased was set too low and that's why it went off.
that one cost me over $100.00 for the guys to come out and check.